GPX-12E

gpx12eph

Standard Emergency Control Unit for Halogen LV lamps.

The GPX12E range of emergency control units are specifically designed for 12V/50W Halogen lamps as well as the drop in replacement LED version types. The unit is designed to produce 100% Light output when in emergency mode. The units comply with BS EN 60598-2-22, BS EN 60924 and SABS 1464: Part 22. Either maintained or non-maintained mode can be used. A safety start circuit is provided that prevents emergency operation until mains is connected. This enables installation without disconnecting or depleting the batteries. A red LED indicates that the battery is being charged and that power (220Vac) has been applied. The unit is housed in a interference free metal housing and is therefore EMI compliant. The unit is protected from any high excess input voltage that may occur naturally or unintentionally by accidently connecting the unit to the incorrect mains supply voltage. The emergency light output is sufficient to satisfy most escape route and anti-panic area lighting requirements. The unit can be used with conventional dimming circuits. All units are designed, developed and manufactured in South Africa. Note 1: The emergency lighting duration and light output may vary due to ambient temperature, cell type and lamp manufacturer. Note 2: The unit may be provided for operation from 110 Vac.
 

LAMP TYPE

 

LIGHT OUTPUT

 

BATTERY CURRENT

 

DURATION

12V/50W Halogen 100% 4A 1 hour
Equivalent LED 100% >350mA Up to 10 hours

SPECIFICATIONS:

Mains voltage tolerance 230Vac +/- 10% 50 Hz
Lamp types 12V 50 Watt Halogen lamps
Emergency lighting duration 1 hour
Mains power consumption 2VA
Battery discharge current <4.0A
Deep discharge protection > 0.8V/cell
Charging current 200 mA
Charge/power indication Red LED
Quiescent current > 1 µA
Dimensions (L x W x H): 184 x 33 x 28mm
Battery: 10 x 4A/hr Ni-Cd
Weight: 230g
Maximum operating temperature +70o C